C8170;DF side registration motor 1 error 1. Object: 1000-sheet finisher, 4000-sheet finisher, Inner finisher;The home position cannot be detected after passing 3s when relocating to the home position.;1 Checking the front DF side registration guide The front DF side registration guide is not assembled properly. If the DF side registration front guide does not move manually, repair the position where restricts the operation.<br>2 Checking the front DF side registration guide drive parts The DF side registration front guide drive parts are not properly attached, or they are faulty. Reattach the DF side registration front guide drive parts. If not repaired, replace them.<br>3 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • DF side registration motor 1 — DF PWB • DF side registration sensor 1 — DF PWB Service Manual — Section 8 ‘PWBs’<br>4 Replacing DF side registration motor 1 DF side registration motor 1 is faulty. Execute U240 [Motor] > [Width Test(A3)] or [Width Test(LD)]. If DF side registration motor 1 does not operate properly, replace it. Maintenanc e Mode List<br>5 Checking DF side registration sensor 1 DF side registration sensor 1 is not properly attached, or it is faulty. Reattach DF side registration sensor 1, then execute U241 [Finisher] > [Width Front HP]. If DF side registration sensor 1 does not operate properly, replace it. Maintenanc e Mode List<br>6 Replacing the DF PWB The DF PWB is faulty. Replace the DF PWB. Upgrade the firmware by using the latest upgrade pack immediately after replacing the DF PWB. Detaching and reattaching the DF PWB Firmware Update
C8180;DF side registration motor 1 error 2. Object: 1000-sheet finisher, 4000-sheet finisher, Inner finisher;J6810/J6811/J6812 (Front DF side registration jam) was detected 2 times continuously.;1 Checking the front DF side registration guide The front DF side registration guide is not assembled properly. If the DF side registration front guide does not move manually, repair the position where restricts the operation.<br>2 Checking the front DF side registration guide drive parts The DF side registration front guide drive parts are not properly attached, or they are faulty. Reattach the front DF side registration guide drive parts.<br>3 Replacing the front DF side registration guide drive parts The front DF side registration guide drive parts are faulty. Replace the front DF side registration guide drive parts.<br>4 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • DF side registration motor 1 — DF PWB • DF side registration sensor 1 — DF PWB Service Manual — Section 8 ‘PWBs’<br>5 Checking DF side registration motor 1 DF side registration motor 1 is faulty. Execute U240 [Motor] > [Width Test(A3)] or [Width Test(LD)]. If DF side registration motor 1 does not operate properly, replace it. Maintenanc e Mode List<br>6 Checking DF side registration sensor 1 DF side registration sensor 1 is not properly attached, or it is faulty. Reattach DF side registration sensor 1, then execute U241 [Finisher] > [Width Front HP]. If DF side registration sensor 1 does not operate properly, replace it. Maintenanc e Mode List<br>7 Replacing the DF PWB The DF PWB is faulty. Replace the DF PWB. Upgrade the firmware by using the latest upgrade pack immediately after replacing the DF PWB. Detaching and reattaching the DF PWB Firmware Update
C8190;DF side registration motor 2 error 1. Object: 1000-sheet finisher, 4000-sheet finisher, Inner finisher;The home position cannot be detected after passing 3s when relocating to the home position.;1 Checking the rear DF side registration guide The rear DF side registration guide is not assembled properly. If the DF side registration rear guide does not move manually, repair the position where restricts the operation.<br>2 Checking the rear DF side registration guide drive parts The DF side registration rear guide drive parts are not properly attached, or they are faulty. Reattach the DF side registration rear guide drive parts. If not repaired, replace them.<br>3 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • DF side registration motor 2 — DF PWB • DF side registration sensor 2 — DF PWB Service Manual — Section 8 ‘PWBs’<br>4 Replacing DF side registration motor 2 DF side registration motor 2 is faulty. Execute U240 [Motor] > [Width Test(A3)] or [Width Test(LD)]. If DF side registration motor 2 does not operate properly, replace it. Maintenanc e Mode List<br>5 Checking DF side registration sensor 2 DF side registration sensor 2 is not properly attached, or it is faulty. Reattach DF side registration sensor 2, then execute U241 [Finisher] > [Width Tail HP]. If DF side registration sensor 2 does not operate properly, replace it. Maintenanc e Mode List<br>6 Replacing the DF PWB The DF PWB is faulty. Replace the DF PWB. Upgrade the firmware by using the latest upgrade pack immediately after replacing the DF PWB. Detaching and reattaching the DF PWB Firmware Update
C8200;DF side registration motor 2 error 2. Object: 1000-sheet finisher, 4000-sheet finisher, Inner finisher;J6910/J6911/J6912 (Rear DF side registration jam) was detected 2 times continuously.;1 Checking the rear DF side registration guide The rear DF side registration guide is not assembled properly. If the DF side registration rear guide does not move manually, repair the position where restricts the operation.<br>2 Checking the rear DF side registration guide drive parts The side registration rear guide drive parts are not properly attached, or they are faulty. Reattach the DF side registration rear guide drive parts. If not repaired, replace them.<br>3 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • DF side registration motor 2 — DF PWB • DF side registration sensor 2 — DF PWB Service Manual — Section 8 ‘PWBs’<br>4 Checking DF side registration motor 2 DF side registration motor 2 is faulty. Execute U240 [Motor] > [Width Test(A3)] or [Width Test(LD)]. If DF side registration motor 2 does not operate properly, replace it. Maintenanc e Mode List<br>5 Checking DF side registration sensor 2 DF width adjustment sensor 2 is not installed properly. Or, it is faulty. Reattach DF side registration sensor 2, then execute U241 [Finisher] > [Width Tail HP]. If DF side registration sensor 2 does not operate properly, replace it. Maintenanc e Mode List<br>6 Replacing the DF PWB The DF PWB is faulty. Replace the DF PWB. Upgrade the firmware by using the latest upgrade pack immediately after replacing the DF PWB. Detaching and reattaching the DF PWB Firmware Update
C8210;DF staple motor front/rear error. Object: 1000-sheet finisher, 4000-sheet finisher, Inner finisher;The home position could not be detected after passing 3s when replacing to the home position at the initial operation.;1 Checking the DF staple unit The DF staple unit is not assembled properly. If the DF staple unit does not move front and back manually, repair the position where restricts the operation.<br>2 Checking the DF staple unit drive parts The DF staple unit drive parts are not properly attached, or they are faulty. Reattach the DF staple unit drive parts. If not repaired, replace them.<br>3 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • DF staple motor — DF PWB • DF staple sensor — DF PWB Service Manual — Section 8 ‘PWBs’<br>4 Replacing the DF staple motor The DF staple motor is faulty. Execute U240 [Motor] > [Staple]. If the DF staple motor does not operate properly, replace the DF staple unit. Maintenanc e Mode List Detaching and reattaching the DF Staple Unit<br>5 Checking the DF staple sensor The DF staple motor is not properly attached, or it is faulty. Reattach the DF staple sensor. Then, replace the DF staple unit if the sensor is not fixed. Detaching and reattaching the DF Staple Unit<br>6 Replacing the DF PWB The DF PWB is faulty. Replace the DF PWB. Upgrade the firmware by using the latest upgrade pack immediately after replacing the DF PWB. Detaching and reattaching the DF PWB Firmware Update
C8230;DF staple motor error 1. Object: 1000-sheet finisher, 4000-sheet finisher, Inner finisher;DF staple JAM is detected 2 times continuously. (The condition of JAM detection for the second time: after the motor is started, home position can’t be detected even 600ms passed.);1 Checking the DF staple unit The DF staple unit is not assembled properly. If the DF staple can’t be done without paper jam, repair the position where restricts the operation.<br>2 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • DF staple unit — DF PWB Service Manual — Section 8 ‘PWBs’<br>3 Replacing the DF staple unit The DF staple unit is faulty. Replace the DF staple unit. Detaching and reattaching the DF Staple Unit<br>4 Replacing the DF PWB The DF PWB is faulty. Replace the DF PWB. Upgrade the firmware by using the latest upgrade pack immediately after replacing the DF PWB. Detaching and reattaching the DF PWB Firmware Update
C8250;DF main tray error 4. Object: 1000-sheet finisher;The lock-up detection signal is 0.7V or less for 10s continuously while driving the DF tray motor.;1 Checking the DF tray The DF tray is not assembled properly. If the DF tray does not move up and down manually, repair the position where restricts the operation.<br>2 Checking the DF tray drive parts The DF tray drive parts are not properly attached, or they are faulty. Reattach the DF tray drive parts. If not repaired, replace them.<br>3 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • DF tray motor — DF PWB Service Manual — Section 8 ‘PWBs’<br>4 Replacing the DF tray motor The DF tray motor is faulty. Replace the DF tray motor if it does not operate properly when checking the operation at U240. Maintenanc e Mode List<br>5 Replacing the DF PWB The DF PWB is faulty. Replace the DF PWB. Upgrade the firmware by using the latest upgrade pack immediately after replacing the DF PWB. Detaching and reattaching the DF PWB Firmware Update
C8260;DF middle motor HP detection error. Object: 1000-sheet finisher, 4000-sheet finisher, Inner finisher;J790X (Middle paddle jam) was detected 2 times continuously.;1 Checking the DF paddle drive components The DF paddle drive components are not properly attached, or it is faulty. Reattach the DF paddle drive components. Or replace.<br>2 Checking connection The connector is not properly connected. Or the wire is faulty. Clean the terminals of the wire connector and reinstall it. If there is no continuity, replace the wire. EDF middle motor — DF PWB EDF paddle sensor — DF PWB Service Manual — Section 8 ‘PWBs’<br>3 Replacing DF middle motor The DF middle motor is faulty. Execute U240 [Motor] > [Middle(H)] or [Middle(L)] Replace the DF middle motor if it does not operate properly. Maintenanc e Mode List<br>4 Checking DF paddle sensor The DF paddle sensor is not properly attached or faulty. Reattach the DF paddle sensor and execute U241 [Finisher] > [Lead Paddle]. Replace the DF paddle sensor if it does not operate properly. Maintenanc e Mode List<br>5 Replacing DF PWB DF PWB is faulty. Replace DF PWB. After replacing the PWB, upgrade the firmware to the latest version. Detaching and reattaching the DF PWB Firmware Update
C8300;Main program error / BF unit communication error. Object: 4000-sheet finisher with the folding unit;After confirming connection with the holding unit, the communication has cut off.;1 Checking the BF set sensor The BF set sensor is not attached properly. Reattach the BF set sensor.<br>2 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • BF PWB — DF PWB Service Manual — Section 8 ‘PWBs’<br>3 Replacing the BF set sensor The BF set sensor is faulty. Execute U241 [Booklet] > [Set]. If the BF set sensor does not operate properly, replace it. Maintenanc e Mode List<br>4 Replacing the BF PWB The BF PWB is faulty. Replace the BF PWB.<br>5 Replacing the DF PWB The DF PWB is faulty. Replace the DF PWB. Upgrade the firmware by using the latest upgrade pack immediately after replacing the DF PWB. Detaching and reattaching the DF PWB Firmware Update
C8310;BF side registration motor 2 error. Object: 4000-sheet finisher with the folding unit;BF side registration sensor 2 does not turn on after passing 1s during the initial operation.;1 Checking the upper BF side registration guide The upper BF side registration guide is not assembled properly. If the BF side registration upper guide does not move front and back manually, repair the position where restricts the operation.<br>2 Checking the upper BF side registration guide drive parts The BF side registration upper guide drive parts are not properly attached, or they are faulty. Reattach the BF side registration upper guide drive parts. If not repaired, replace them.<br>3 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • BF side registration motor 2 — BF PWB • BF side registration sensor 2 — BF PWB Service Manual — Section 8 ‘PWBs’<br>4 Replacing BF side registration motor 2 BF side registration motor 2 is faulty. Replace BF side registration motor 2 if it does not operate properly when checking the operation at U240. Maintenanc e Mode List<br>5 Checking BF side registration sensor 2 BF side registration sensor 2 is not properly attached, or it is faulty. Reattach BF side registration sensor 2, then execute U241 [Booklet] > [Width Down HP]. If BF side registration sensor 2 does not operate properly, replace it. Maintenanc e Mode List<br>6 Replacing the BF PWB The BF PWB is faulty. Replace the BF PWB.
C8320;BF adjustment motor error. Object: 4000-sheet finisher with the folding unit;At the initialization, turning on of the BF adjustment sensor is not detected after 2.5s passes.;1 Checking the BF shift belt The BF shift belt is not assembled properly. If the BF shift belt is not operated manually, repair the part that restricts the operation.<br>2 Checking the BF shift belt drive parts The BF shift belt drive parts are not properly attached, or they are faulty. Reattach the BF shift belt drive parts. If the belt comes off, reattach it. If not repaired, replace the BF shift belt drive parts.<br>3 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • BF adjusting motor 1, 2 — BF PWB • BF adjusting sensor 1, 2 — BF PWB Service Manual — Section 8 ‘PWBs’<br>4 Replacing BF adjustment motors 1, 2 BF adjustment motors 1, 2 are faulty. Execute U240 [Booklet] > [Bundle Down] or [Bundle Up]. If DF adjusting motor 1 or 2 does not operate properly, replace it. Maintenanc e Mode List<br>5 Checking BF adjustment sensors 1, 2 BF adjustment sensors 1, 2 are not properly attached, or they are faulty. Reattach BF adjusting sensor 1 or 2, then execute U241 [Booklet] > [Bundle Down HP] or [Bundle Up HP]. If BF adjusting sensor 1 or 2 does not operate properly, replace it. Maintenanc e Mode List<br>6 Replacing the BF PWB The BF PWB is faulty. Replace the BF PWB.
C8330;BF blade motor error. Object: 4000-sheet finisher with the folding unit;The BF blade sensor does not turn on after passing 3s during the initial operation.;1 Checking the BF blade The BF blade is not assembled properly. If the BF blade does not operation manually, repair the position where restricts the operation.<br>2 Checking the BF blade drive parts The BF blade drive parts are not properly attached, or they are faulty. Reattach the BF blade drive parts. If not repaired, replace them.<br>3 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • BF blade motor — BF PWB • BF blade sensor — BF PWB Service Manual — Section 8 ‘PWBs’<br>4 Replacing the BF blade motor The BF blade motor is faulty. Execute U240 [Booklet] > [Blade]. If the BF blade motor does not operate properly, replace it. Maintenanc e Mode List<br>5 Checking the BF blade sensor The BF blade sensor is not properly attached. Reattach the BF blade sensor, then execute U241 [Booklet] > [Blade HP]. If the BF blade sensor does not operate properly, replace it. Maintenanc e Mode List<br>6 Replacing the BF PWB The BF PWB is faulty. Replace the BF PWB.
C8340;BF staple motor error 1. Object: 4000-sheet finisher with the folding unit;BF staple JAM is detected 2 times continuously. (The condition of JAM detection for the second time: after the motor is started, home position can’t be detected even 600ms passed.);1 Checking the BF staple unit The BF staple unit is not assembled properly. If the BF staple unit does not operation manually, repair the position where restricts the operation.<br>2 Checking the BF staple unit drive parts The BF staple unit drive parts are not properly attached, or they are faulty. Reattach the BF staple unit drive parts. If not repaired, replace them.<br>3 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • BF staple unit — DF PWB Service Manual — Section 8 ‘PWBs’<br>4 Replacing the BF staple unit The BF staple motor is faulty. Execute U240 [Booklet] > [Staple]. If the BF staple motor does not operate properly, replace the BF staple unit. Maintenanc e Mode List<br>5 Replacing the BF PWB The BF PWB is faulty. Replace the BF PWB.
C8350;BF side registration motor 1 error. Object: 4000-sheet finisher with the folding unit;BF side registration sensor 1 does not turn on after passing 1s during the initial operation.;1 Checking the lower BF side registration guide The lower BF side registration guide is not assembled properly. If the BF side registration lower guide does not operation manually, repair the position where restricts the operation.<br>2 Checking the lower BF side registration guide drive parts The BF side registration lower guide drive parts are not properly attached, or they are faulty. Reattach the BF side registration lower guide drive parts. If not repaired, replace them.<br>3 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • BF side registration motor 1 — BF PWB • BF side registration sensor 1 — BF PWB Service Manual — Section 8 ‘PWBs’<br>4 Replacing BF side registration motor 1 BF side registration motor 1 is faulty. Replace BF side registration motor 1 if it does not operate properly when checking the operation at U240. Maintenanc e Mode List<br>5 Checking BF side registration sensor 1 BF side registration sensor 1 is not properly attached, or it is faulty. Reattach BF side registration sensor 1, then execute U241 [Booklet] > [Width Up HP]. If BF side registration sensor 1 does not operate properly, replace it. Maintenanc e Mode List<br>6 Replacing the BF PWB The BF PWB is faulty. Replace the BF PWB.
C8360;BF main motor error. Object: 4000-sheet finisher with the folding unit;The lock-up signal was detected for 1s continuously during the motor operation.;1 Checking the BF conveying roller The BF conveying roller is not assembled properly. If the BF conveying roller is not rotated manually, repair the part that restricts the operation.<br>2 Checking the BF conveying roller drive parts The BF conveying roller drive parts are not properly attached, or they are faulty. Reattach the BF conveying roller drive parts. If not repaired, replace them.<br>3 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • BF main motor — BF PWB Service Manual — Section 8 ‘PWBs’<br>4 Replacing the BF main motor The BF main motor is faulty. Execute U240 [Booklet] > [Blade]. If the BF blade motor does not operate properly, replace it. Maintenanc e Mode List<br>5 Replacing the BF PWB The BF PWB is faulty. Replace the BF PWB.
C8370;BF staple motor error 2. Object: 4000-sheet finisher with the folding unit;BF staple JAM is detected 2 times continuously. (The condition of JAM detection for the second time: during the motor is operating, home position can’t be detected even 600ms passed.);1 Checking the BF staple unit The BF staple unit is not assembled properly. If the BF staple unit does not operation manually, repair the position where restricts the operation.<br>2 Checking the BF staple unit drive parts The BF staple unit drive parts are not properly attached, or they are faulty. Reattach the BF staple unit drive parts. If not repaired, replace them.<br>3 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • BF staple unit — DF PWB Service Manual — Section 8 ‘PWBs’<br>4 Replacing the BF staple motor The BF staple motor is faulty. Execute U240 [Booklet] > [Staple]. If the BF staple motor does not operate properly, replace it. Maintenanc e Mode List<br>5 Replacing the BF staple unit The BF staple unit is faulty. Replace the BF staple unit.<br>6 Replacing the BF PWB The BF PWB is faulty. Replace the BF PWB.
C8380;BF eject pressure release motor error. Object: 4000-sheet finisher with the folding unit;Operation is not complete when passing 3s after starting up the BF eject pressure release motor;1 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • The BF eject pressure release motor — DF PWB • The BF eject pressure release HP sensor — DF PWB<br>2 Repacing the BF eject pressure release motor The BF eject pressure release motor is faulty Execute U240 [Booklet] > [Staple]. If the BF staple motor does not operate properly, replace it.<br>3 Replacing the BF eject pressure release HP sensor The BF eject pressure release HP sensor is faulty Replace the BF eject pressure release HP sensor<br>4 Replacing the BF PWB The BF PWB is faulty. Replace the BF PWB.
C8390;BF paddle motor error. Object: 4000-sheet finisher with the folding unit;Operation is not complete when passing 250ms after starting up the BF paddle motor;1 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. EBF eject pressure release motor — BF PWB EBF eject pressure release HP sensor — BF PWB<br>2 Replacing the BF paddle motor The BF paddle motor is faulty Execute U240 mBooklet n > mPaddle n. Replace the BF paddle motor if it does not operate properly.<br>3 Replacing the BF paddle HP sensor The BF paddleHP sensor is faulty Replace the BF paddle HP sensor<br>4 Replacing the BF PWB The BF PWB is faulty. Replace the BF PWB.
C8400;BF conveying tray motor error. Object: 4000-sheet finisher with the folding unit;Lock signal is detected for 100ms when passing 1s after starting the BF conveying tray motor drive;1 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. ETthe BF conveying tray motor — BF PWB<br>2 Replacing the BF conveying tray motor Tthe BF conveying tray motor is faulty Execute U240 mBooklet n > mFeed Tray n. Replace the BF conveying tray motor if it does not operate properly.<br>3 Replacing the BF PWB The BF PWB is faulty. Replace the BF PWB.
C8410;PH slide motor error 1. Object: 4000-sheet finisher or 1000-sheet finisher with the punch unit;The PH slide sensor does not turn on after shifting 30mm when relocating to the home position.;1 Checking the punch unit The punch unit is not assembled properly. If the punch slide section does not move front and back manually, repair the position where restricts the operation.<br>2 Checking the PH drive parts The PH drive parts are not attached properly, or faulty. Reattach the PH drive parts. If not repaired, replace them.<br>3 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • PH slide motor — PH PWB • PH slide sensor — PH PWB • PH PWB — DF PWB Service Manual — Section 8 ‘PWBs’<br>4 Replacing the PH slide motor The PH slide motor is faulty. Execute U240 [Motor] > [Punch Move]. If the PH slide motor does not operate properly, replace the DF staple unit. Maintenanc e Mode List<br>5 Checking the PH slide sensor The PH slide sensor is not properly attached, or it is faulty. Reattach the PH slide sensor, then check the sensor operation by executing U241. If the PH slide sensor does not operate properly, replace it. Maintenanc e Mode List<br>6 Replacing the PH PWB The PH PWB is faulty. Replace the PH PWB. Detaching and reattaching the PH PWB (PH-7A/C/D Installation Guide)<br>7 Replacing the DF PWB The DF PWB is faulty. Replace the DF PWB. Upgrade the firmware by using the latest upgrade pack immediately after replacing the DF PWB. Detaching and reattaching the DF PWB Firmware Update
C8420;PH slide motor error 2. Object: 4000-sheet finisher or 1000-sheet finisher with the punch unit;The paper edge cannot be detected even if shifting 30mm when detecting the paper edge.;1 Checking the punch unit The punch unit is not assembled properly. If the punch slide section does not move front and back manually, repair the position where restricts the operation.<br>2 Checking the PH drive parts The PH drive parts are not attached properly, or faulty. Reattach the PH drive parts. If not repaired, replace them.<br>3 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • PH slide motor — PH PWB • PH paper edge sensor 1, 2 — PH PWB • PH PWB — DF PWB Service Manual — Section 8 ‘PWBs’<br>4 Replacing the PH slide motor The PH slide motor is faulty. Execute U240 [Motor] > [Punch Move]. If the PH slide motor does not operate properly, replace the DF staple unit. Maintenanc e Mode List<br>5 Checking the PH paper edge sensors 1, 2 PH paper edge sensors 1, 2 are not properly attached, or they are faulty. Reattach PH paper edge sensor 1 or 2, then check the sensor operation by executing U241. If PH paper edge sensor 1 or 2 does not operate properly, replace it. Maintenanc e Mode List<br>6 Replacing the PH PWB The PH PWB is faulty. Replace the PH PWB. Detaching and reattaching the PH PWB (PH-7A/C/D Installation Guide)<br>7 Replacing the DF PWB The DF PWB is faulty. Replace the DF PWB. Upgrade the firmware by using the latest upgrade pack immediately after replacing the DF PWB. Detaching and reattaching the DF PWB Firmware Update
C8430;Main program error / Punch unit communication error. Object: 1000-sheet finisher, 4000-sheet finisher, Inner finisher (When punch unit is installed);The communication could not succeed after confirming the connection with the punch unit.;1 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • PH PWB — DF PWB Service Manual — Section 8 ‘PWBs’<br>2 Replacing the PH PWB The PH PWB is faulty. Replace the PH PWB. Detaching and reattaching the PH PWB (PH-7A/C/D Installation Guide)<br>3 Replacing the DF PWB The DF PWB is faulty. Replace the DF PWB. Upgrade the firmware by using the latest upgrade pack immediately after replacing the DF PWB. Detaching and reattaching the DF PWB Firmware Update
C8500;Main program error / Mail Box communication error. Object: 4000-sheet finisher with the mail box;The communication failed after confirming the connection with the mail box.;1 Resetting the main power The PWB malfunctions. Turn the power switch and the main power switch off . After 5s passes, turn the main power switch and the power switch on.<br>2 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • MT PWB — DF PWB Service Manual — Section 8 ‘PWBs’<br>3 Replacing the MT PWB The MT PWB is faulty. Replace the MT PWB.<br>4 Replacing the DF PWB The DF PWB is faulty. Replace the DF PWB. Upgrade the firmware by using the latest upgrade pack immediately after replacing the DF PWB. Detaching and reattaching the DF PWB Firmware Update
C8510;MB conveying motor error 1. Object: 4000-sheet finisher with the mail box;The MT home position sensor does not turn on after passing 10s during the initial operation.;1 Checking the MT conveying roller The MT conveying roller is not assembled properly. If the MT conveying roller is not rotated manually, repair the part that restricts the operation.<br>2 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • MT conveying motor — MT PWB • MT home position sensor — MT PWB Service Manual — Section 8 ‘PWBs’<br>3 Replacing the MT conveying motor The MT conveying motor is faulty. Execute U240 [Mail Box] > [Conv]. If the MT conveying motor does not operate properly, replace it. Maintenanc e Mode List<br>4 Checking the MT home position sensor The MT home position is not properly attached, or it is faulty. Reattach the MT home position sensor, then execute U241 [Mail Box] > [Motor HP]. If the MT home position sensor does not operate properly, replace it. Maintenanc e Mode List<br>5 Replacing the MT PWB The MT PWB is faulty. Replace the MT PWB.
C8520;MB conveying motor error 2. Object: 4000-sheet finisher with the mail box;The MT home position sensor does not turn off after passing 2s during the standby operation.;1 Checking the MT conveying roller The MT conveying roller is not assembled properly. If the MT conveying roller is not rotated manually, repair the part that restricts the operation.<br>2 Checking the MT conveying roller drive parts The MT conveying roller drive parts are not properly attached, or they are faulty. Reattach the MT conveying roller drive parts.<br>3 Replacing the MT conveying roller drive parts The MT conveying roller drive parts are faulty. Replace the MT conveying roller drive parts.<br>4 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • MT conveying motor — MT PWB • MT home position sensor — MT PWB Service Manual — Section 8 ‘PWBs’<br>5 Replacing the MT conveying motor The MT conveying motor is faulty. Execute U240 [Mail Box] > [Conv]. If the MT conveying motor does not operate properly, replace it. Maintenanc e Mode List<br>6 Checking the MT home position sensor The MT home position is not properly attached, or it is faulty. Reattach the MT home position sensor, then execute U241 [Mail Box] > [Motor HP]. If the MT home position sensor does not operate properly, replace it. Maintenanc e Mode List<br>7 Replacing the MT PWB The MT PWB is faulty. Replace the MT PWB.
C8600;DF adjusting release motor error. Object: 100-sheet staple finisher;Change of DF adjusting release HP sensor was not detected when driving the DF adjusting release motor for 3s in the direction of HP sensor change;1 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminals of the wire connector and reinstall it. If there is no continuity, replace the wire. EDF adjusting release motor — DF PWB EDF adjusting release HP sensor — DF PWB<br>2 Replacing the DF adjusting release motor The DF adjusting release motor is faulty. Execute U240 mMotor n > mMatch Pressure] Replace the DF adjusting release motor if it does not operate properly.<br>3 Replacing the adjusting release HP sensor The DF adjusting release HP sensor is faulty. Execute U241 mFinisher n > mMatch Coro HP] Replace the DF adjusting release HP sensor if it does not operate properly.<br>4 Replacing BF PWB BF PWB is faulty. Replace BF PWB.
C8610;DF pull-in guide release motor error. Object: 100-sheet staple finisher;Change of DF pull-in guide release HP sensor was not detected when driving the DF pull-in guide release motor for 3s in the direction of HP sensor change;1 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminals of the wire connector and reinstall it. If there is no continuity, replace the wire. EDF pull-in guide release motor — DF PWB EDF pull-in guide release HP sensor — DF PWB<br>2 Replacing the DF pull-in guide release motor The DF pull-in guide release motor is faulty. Execute U240 mMotor n > mBeat n Replace the DF adjusting release motor if it does not operate properly.<br>3 Replacing the DF pull-in guide release HP sensor The DF pull-in guide release HP sensor is faulty. Execute U241 mFinisher n > mRear Beat HP n Replace the DF adjusting release HP sensor if it does not operate properly.<br>4 Replacing BF PWB BF PWB is faulty. Replace BF PWB.
C8620;DF pull-in pulley pressure release motor error. Object: 100-sheet staple finisher;Change of DF pull-in pulley pressure release HP sensor was not detected when driving the DF pull-in pulley pressure release motor for 3s in the direction of HP sensor change;1 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminals of the wire connector and reinstall it. If there is no continuity, replace the wire. EDF pull-in guide release HP sensor — DF PWB EDF pull-in guide release HP sensor — DF PWB<br>2 Replacing the DF pull-in pulley pressure release motor The DF pull-in pulley pressure release motor is faulty. Execute U240 mMotor n > mPull Pressure n Replace the DF pull-in pulley pressure release motor if it does not operate properly.<br>3 Replacing the DF pull-in guide release HP sensor The DF pull-in pulley pressure release HP sensor is faulty. Execute U241 mFinisher n > mPull Coro HP n Replace the DF pull-in pulley pressure release HP sensor if it does not properly operate.<br>4 Replacing BF PWB BF PWB is faulty. Replace BF PWB.
C8630;Eject pressure release motor error. Object: 100-sheet staple finisher;Change of the eject pressure release HP switch was not detected when driving the eject pressure release motor for 3s in the direction of HP sensor change.;1 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminals of the wire connector and reinstall it. If there is no continuity, replace the wire. EDF eject pressure release motor — DF PWB EDF eject pressure release HP sensor — DF PWB<br>2 Replacing the DF eject pressure release motor The DF eject release motor is faulty. Execute U240 mMotor n > mEject Unlock n Replace the DF eject release motor if it does not operate properly.<br>3 Checking the DF eject pressure release sensor The DF eject pressure release sensor is not attached properly or faulty. Reattach the DF eject pressure release HP sensor and execute U241 mFinisher n > mEject Press HP n. Replace the DF eject pressure release HP sensor if it does not operate properly.<br>4 Replacing the DF PWB The DF PWB is faulty. Replace DF PWB. After replacing the PWB, upgrade the firmware to the latest version. Detaching and reattaching the DF PWB Firmware Update
C8640;DF side registration motor 1 error. Object: 100-sheet staple finisher;Change of DF side registration HP sensor 1 was not detected when driving the DF side registration motor 1 for 3s in the direction of HP sensor change;1 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminals of the wire connector and reinstall it. If there is no continuity, replace the wire. EDF side registration motor 1 — DF PWB EDF side registration HP sensor 1 — DF PWB<br>2 Replacing DF side registration motor 1 The connector is not properly connected. Or the wire is faulty. Execute U240 mMotor n > mWidth Test n Replace DF side registration motor 1 if it does not operate properly.<br>3 Checking DF side registration HP sensor DF side registration motor 1 is faulty. DF side registration sensor 1 is not properly attached or faulty. Reattach DF side registration sensor 1 and execute U241 [Finisher] > [Width Front HP]. Replace DF side registration HP sensor 1 if it does not operate properly.<br>4 Replacing the DF PWB The DF PWB is faulty. Replace DF PWB. After replacing the PWB, upgrade the firmware to the latest version. Detaching and reattaching the DF PWB Firmware Update
C8650;DF side registration motor 2 error. Object: 100-sheet staple finisher;Change of DF side registration HP sensor 2 was not detected when driving the DF side registration motor 2 for 3s in the direction of HP sensor change;1 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminals of the wire connector and reinstall it. If there is no continuity, replace the wire. EDF side registration motor 2 — DF PWB EDF side registration HP sensor 2 — DF PWB<br>2 Replacing DF side registration motor 2 The DF side registration motor 2 is faulty. Execute U240 mMotor n > mWidth Test n Replace DF side registration motor 2 if it does not operate properly.<br>3 Checking the DF side registration HP sensor 1 DF side registration sensor 2 is not properly attached or faulty. Reattach DF side registration sensor 2 and execute U241 [Finisher] > [Width Tail HP]. Replace DF side registration motor 2 if it does not operate properly.<br>4 Replacing the DF PWB The DF PWB is faulty. Replace DF PWB. After replacing the PWB, upgrade the firmware to the latest version. Detaching and reattaching the DF PWB Firmware Update
C8700;DF bundle eject motor 1 error. Object: 100-sheet staple finisher;Change of DF bundle eject HP sensor 1 was not detected when driving the DF bundle eject motor 1 for 3s in the direction of HP sensor change;1 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminals of the wire connector and reinstall it. If there is no continuity, replace the wire. EDF bundle eject motor 1 — DF PWB EDF bundle eject HP sensor 1 — DF PWB<br>2 Replacing DF bundle eject motor 1 The bundle eject motor 1 is faulty. Execute U240 mMotor n > mBundle Up n Replace the DF bundle eject motor 1 if it does not operate properly.<br>3 Checking the DF paper stack eject sensor The DF bundle eject HP sensor 1 is not attached properly or faulty. DF PWB is faulty. Reattach the DF bundle eject HP sensor 1 and execute U241 mFinisher n > mBundle Eject HP1 n. Replace the DF bundle eject HP sensor 1 if it does not properly operate.<br>4 Replacing the DF PWB The DF PWB is faulty. Replace DF PWB. After replacing the PWB, upgrade the firmware to the latest version. Detaching and reattaching the DF PWB Firmware Update
C8710;DF bundle eject motor 2 error. Object: 100-sheet staple finisher;Change of DF bundle eject HP sensor 2 was not detected when driving the DF bundle eject motor 2 for 3s in the direction of HP sensor change;1 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminals of the wire connector and reinstall it. If there is no continuity, replace the wire. EDF bundle eject motor 2 — DF PWB EDF bundle eject HP sensor 2 — DF PWB<br>2 Replacing DF bundle eject motor 2 The bundle eject motor 2 is faulty. Execute U240 mMotor n > mBundle Up n Replace the DF bundle eject motor 2 if it does not operate properly.<br>3 Checking the DF bundle eject HP sensor 2 The DF bundle eject HP sensor 2 is not attached properly or faulty. Reattach the DF bundle eject HP sensor 2 and execute U241 mFinisher n > mBundle Eject HP2 n. Replace the DF bundle eject HP sensor 2 if it does not properly operate.<br>4 Replacing the DF PWB The DF PWB is faulty. Replace DF PWB. After replacing the PWB, upgrade the firmware to the latest version. Detaching and reattaching the DF PWB Firmware Update
C8720;DF eject paddle motor error. Object: 100-sheet staple finisher;Change of DF eject paddle HP sensor was not detected when driving the DF eject paddle motor for 3s in the direction of HP sensor change;1 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminals of the wire connector and reinstall it. If there is no continuity, replace the wire. EDF eject paddle motor — DF PWB EDF eject paddle HP sensor — DF PWB<br>2 Replacing the DF paddle motor The DF paddle motor is faulty. Execute U240 mMotor n > mTray Eject Paddle n Replace the DF eject paddle motor if it does not operate properly.<br>3 Checking the DF eject sensor The DF eject paddle sensor is not properly attached or faulty. Reattach the DF eject paddle HP sensor and execute U241 [Finisher] > [Eject Paddle HP]. Replace the DF eject paddle HP sensor if it does not operate properly.<br>4 Replacing the DF PWB The DF PWB is faulty. Replace DF PWB. After replacing the PWB, upgrade the firmware to the latest version. Detaching and reattaching the DF PWB Firmware Update
C8730;DF eject paper trailing edge holding motor error. Object: 100-sheet staple finisher;Change of DF eject paper trailing edge holding HP sensor was not detected when driving the DF eject paper trailing edge holding motor for 3s in the direction of HP sensor change;1 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminals of the wire connector and reinstall it. If there is no continuity, replace the wire. EDF eject paper trailing edge holding motor — DF PWB EDF eject paper trailing edge holding HP sensor — DF PWB<br>2 Replacing the DF eject paper trailing edge holding motor The DF eject paper trailing edge holding motor is faulty. Execute U240 mMotor n > mPress Paper n Replace the DF eject paper trailing edge holding motor if it does not operate properly.<br>3 Checking the DF eject paper trailing edge holding HP sensor DF eject paper holding sensor is not properly attached or faulty. Reattach the DF exit paddle HP sensor and execute U241 [Finisher] > [Press Paper HP]. Replace the DF eject paper trailing edge holding HP sensor if it does not operate properly.<br>4 Replacing the DF PWB The DF PWB is faulty. Replace DF PWB. After replacing the PWB, upgrade the firmware to the latest version. Detaching and reattaching the DF PWB Firmware Update
C8740;DF eject support guide motor error. Object: 100-sheet staple finisher;Change of DF eject support guide HP sensor was not detected when driving the DF support guide motor for 3s in the direction of HP sensor change;1 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminals of the wire connector and reinstall it. If there is no continuity, replace the wire. EDF eject holding guide motor — DF PWB EDF eject holding guide HP sensor — DF PWB<br>2 Replacing the DF eject support guide motor DF eject support guide motor is faulty. Execute U240 mMotor n > mEject Guide n Replace the DF eject support guide motor if it does not operate properly.<br>3 Replacing the DF eject support guide HP sensor DF bundle support guide sensor is not attached properly or faulty. DF PWB is faulty. Reattach the DF eject support guide HP sensor and execute U241 mFinisher n > mEject Guide n. Replace the DF eject paper trailing edge holding HP sensor if it does not operate properly.<br>4 Replacing the DF PWB The DF PWB is faulty. Replace DF PWB. After replacing the PWB, upgrade the firmware to the latest version. Detaching and reattaching the DF PWB Firmware Update
C8800;Main program error / Engine — DF communication error (DF). Object: 1000-sheet finisher, 4000-sheet finisher, Inner finisher;1. When turning on the power, there was an error in the main program.<br>2. The communication error between the Engine and DF is detected 10 times continuously.<br>3. The ready signal is not notified from the DF within 6s after the communication starts.;1 Resetting the main power The program does not start up properly. Turn the power switch and the main power switch off . After 5s passes, turn the main power switch and the power switch on.<br>2 Firmware upgrade The firmware is not the latest version. Upgrade the DP firmware to the latest version. Firmware Update<br>3 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • DF PWB — Engine PWB Service Manual — Section 8 ‘PWBs’<br>4 Replacing the DF PWB The DF PWB is faulty. Replace the DF PWB. Upgrade the firmware by using the latest upgrade pack immediately after replacing the DF PWB. Detaching and reattaching the DF PWB Firmware Update<br>5 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version Firmware Update<br>6 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB. Detaching and reattaching the Engine PWB
C8810;DF-SubCPU communication error. Object: 100-sheet staple finisher;Communication with SubCPU fails 3 times continuously.;Object: 100-sheet staple finisher<br>1 Firmware upgrade The firmware is not the latest version. Upgrade the DF firmware to the latest version.<br>2 Replacing the DF PWB The DF PWB is faulty. Replace the DF PWB. Upgrade the firmware by using the latest upgrade pack immediately after replacing the DF PWB. Detaching and reattaching the DF PWB Firmware Update
C8900;DF backup error. Object: 1000-sheet finisher, 4000-sheet finisher, Inner finisher, 100-sheet staple finisher (For internal counting);Write data and the read data mismatch 3 times continuously.;Object: 1000-sheet finisher, 4000-sheet finisher, Inner finisher, 100-sheet staple finisher (For internal counting)<br>1 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminals of the wire connector and reinstall it. If there is no continuity, replace the wire. EDF PWB — Engine PWB Service Manual — Section 8 ‘PWBs’<br>2 Replacing the DF PWB The DF PWB is faulty. Replace the DF PWB. Upgrade the firmware by using the latest upgrade pack immediately after replacing the DF PWB. Detaching and reattaching the DF PWB Firmware Update
C8930;BF unit backup error. Object: 1000-sheet finisher, 4000-sheet finisher, Inner finisher, 100-sheet staple finisher (For internal counting);Write data and read data mismatch 3 times continuously.;Object: 1000-sheet finisher, 4000-sheet finisher, Inner finisher, 100-sheet staple finisher (For internal counting)<br>1 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminals of the wire connector and reinstall it. If there is no continuity, replace the wire. EBF PWB — DF PWB Service Manual — Section 8 ‘PWBs’<br>2 Replacing BF PWB BF PWB is faulty. Replace BF PWB.<br>3 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
C9000;Main program error / DP communication error. Object: Document processor;The document processor cannot be communicated.;Object: Document processor<br>1 Firmware upgrade The firmware version between the main unit and the document processor mismatches. Upgrade the firmware for the main unit and the document processor to the latest version. Firmware Update<br>2 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • DP PWB — Engine PWB Service Manual — Section 8 ‘PWBs’<br>3 Replacing the DP PWB The DP PWB is faulty. Replace the DP PWB. Detaching and reattaching the DF PWB<br>4 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB. Detaching and reattaching the Engine PWB
C9040;DP lift motor ascend error. Object: Dual scan DP and mechanically reversed DP with the DP feed belt;Turning on of the DP lift upper limit sensor could not be detected after passing 3000 pulses during the DP lift motor ascend drive. That status was continued 5 times or more.;Object: Dual scan DP and mechanically reversed DP with the DP feed belt<br>1 Checking the original lift plate The original lift plate is not attached properly. Or, the fulcrum located at the back side of the machine for the original lift plate is broken. If the original lift plate does not move up and down manually, repair the position where there is stuck. If damaged, replace it.<br>2 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • DP lift motor — DP PWB • DP lift upper limit sensor — DP PWB Service Manual — Section 8 ‘PWBs’<br>3 Replacing the DP lift motor The DP lift motor is faulty. Execute U243 [Lift Motor]. If the DP lift motor does not operate properly, replace it. Maintenanc e Mode List<br>4 Checking the DP lift upper limit sensor The DP lift upper limit sensor is not properly attached, or it is faulty. Reattach the DP lift upper limit sensor and execute U244 [Lift U-Limit]. If the sensor does not operate properly, replace it. Maintenanc e Mode List<br>5 Replacing the DP PWB The DP PWB is faulty. Replace the DP PWB. Detaching and reattaching the DF PWB
C9050;DP lift motor descend error. Object: Dual scan DP and mechanically reversed DP with the DP feed belt;Turning on of the DP lift lower limit sensor could not be detected after passing 3000 pulses during the DP lift motor descend drive. (The recovery is 3 times.);Object: Dual scan DP and mechanically reversed DP with the DP feed belt<br>1 Checking the original lift plate The DP original lift plate is not properly attached. If the original lift plate does not move up and down manually, repair the position where restricts the operation.<br>2 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • DP lift motor — DP PWB • DP lift lower limit sensor — DP PWB Service Manual — Section 8 ‘PWBs’<br>3 Replacing the DP lift motor The DP lift motor is faulty. Execute U243 [Lift Motor]. If the DP lift motor does not operate properly, replace it. Maintenanc e Mode List<br>4 Checking the DP lift lower limit sensor The DP lift lower limit sensor is not properly attached, or it is faulty. Reattach the DP lift lower limit sensor and execute U244 [Lift L-Limit]. If the sensor does not operate properly, replace it. Maintenanc e Mode List<br>5 Replacing the DP PWB The DP PWB is faulty. Replace the DP PWB. Detaching and reattaching the DF PWB
C9060;DP EEPROM error. Object: Document processor;The writing data and the reading data into the EEPROM mismatch.;1 Checking the EEPROM The EEPROM is not properly installed. Reattach the EEPROM on the DP PWB. Detaching and reattaching the DF PWB<br>2 Replacing the DP PWB The DP PWB is faulty. Replace the DP PWB. Detaching and reattaching the DF PWB<br>3 Replacing the EEPROM The EEPROM is faulty. Replace the EEPROM on the DP PWB, then execute U411. Detaching and reattaching the DF PWB Maintenanc e Mode List
C9070;DP — SHD communication error. Object: Dual scan DP;The communication error between the DP PWB and the DP SHD PWB is detected during the communication.;1 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • DP SHD PWB — DP PWB Service Manual — Section 8 ‘PWBs’<br>2 Replacing the DPSHD PWB The DPSHD PWB is faulty. Replace the DPSHD PWB.<br>3 Replacing the DP PWB The DP PWB is faulty. Replace the DP PWB. Detaching and reattaching the DF PWB
C9080;LED failure detection. Object: Dual scan DP For internal count;After 4 blocks of the LED lamps of the DPCIS are lit when turning on the power, the acquired peak value of some blocks is the reference value or less.;Object: Dual scan DP For internal count<br>1 Checking the LED lamp The LED lamp of the DPCIS does not light. Execute U203 to confirm that the LED lamp of the DPCIS does not light. Go to the next step. Maintenanc e Mode List<br>2 Checking the DPSHD PWB The DPSHD PWB is not properly connected. Reconnect the DPSHD PWB to the DPCIS.<br>3 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • DP SHD PWB — DP PWB Service Manual — Section 8 ‘PWBs’<br>4 Executing U411 DP scanning is not properly adjusted. Execute U411 [DP FD(ChartB)] and [DP FD(ChartA)]. Maintenanc e Mode List<br>5 Replacing the DPCIS The DPCIS is faulty. Replace the DPCIS, and then execute U091 and U411. Detaching and reattaching the DP CIS Maintenanc e Mode List<br>6 Replacing the DPSHD PWB The DPSHD PWB is faulty. Replace the DPSHD PWB.
C9180;DP feed-shift motor error. Object: Mechanically reversed DP with the DP feed belt. Remarks: When detecting the DP feed-shift motor error (C9180) (up to 2 times), display J9002.;HP can’t be detected even after the retrying process for the HP detection of the DP feed-shift guide for 3 times continuously. * HP detection of the DP feed-shift guide: When the DP feed-shift motor moves to HP, if HP can’t be detected even driving the DP feed-shift motor for 1 round, the retry is done.;Object: Mechanically reversed DP with the DP feed belt<br>Remarks: When detecting the DP feed-shift motor error (C9180) (up to 2 times), display J9002.<br>1 Removing the original The original accordion jam in the guide between the DP reversing tray and the DP registration roller (The position is not visible when the DP upper cover is opened) Remove the original which is stuck in the guide between the DP reversing tray and DP registration roller.<br>2 Cleaning the original conveying guide. Sticky foreign objects adhere to the original conveying guide Clean the original conveying guide.<br>3 Resetting the main power The DP feed-shift motor is not controlled correctly. Turn the power switch and the main power switch off . After 5s passes, turn the main power switch and the power switch on.<br>4 Checking the DP feed-shift motor The DP feed-shift motor is not rotated correctly. Or, there is an excess load. After removing the DP feed-shift motor and repair it by rotating the drive section manually, reattach it.<br>5 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the connector terminal of the wire and reconnect. If there is no continuity, replace the wire. EDP feed-shift motor — DP PWB EDP feed-shift sensor — DP PWB Service Manual — Section 8 ‘PWBs’<br>6 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version Firmware Update<br>7 Replacing the DP feed-shift motor The DP feed-shift motor is faulty. Replace the DP feed-shift motor.<br>8 Checking the DP feed-shift sensor The DP feed-shift sensor is not attached properly or faulty. Reattach the DP feed-shift sensor. If not repaired, replace it.<br>9 Replacing the DP PWB The DP PWB is faulty. Replace the DP PWB. Detaching and reattaching the DF PWB
C9500;Image processing PWB error (Scanner);;1 Checking the connection FFC is not connected properly. Or it is faulty. Clean the FFC terminals of the following FFC and reconnect them. If the FFC terminal is deformed or broken, replace the FFC. • Engine PWB — Main PWB Service Manual — Section 8 ‘PWBs’<br>2 Replacing the main PWB The main PWB is faulty. Replace the main PWB. Detaching and reattaching the Main PWB<br>3 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB. Detaching and reattaching the Engine PWB
C9510;Image processing circuit error (DP);;1 Checking the DP relay PWB The DP relay PWB is not properly attached. Reattach the DP relay PWB.<br>2 Checking the connection The SATA cable is not properly connected, or it is faulty. Reconnect the connector of the following SATA cable. If there is no continuity, replace the SATA cable. • DP SHD PWB — DP relay PWB Service Manual — Section 8 ‘PWBs’<br>3 Replacing the DPSHD PWB The DPSHD PWB is faulty. Replace the DPSHD PWB.<br>4 Replacing the DP relay PWB The DP relay PWB is faulty. Replace the DP relay PWB.<br>5 Replacing the main PWB The main PWB is faulty. Replace the main PWB. Detaching and reattaching the Main PWB
C9540;Backup data error;When multiple parts are replaced at the same time, the internal data is changed and it interferes with the machine operation. Consequently, the main unit cannot recover.;1 Checking the PWB Multiple PWBs were replaced at the same time. Recover to the original, if 2 or more of the following related parts were replaced at the same time. • Related parts: Memory, each PWB<br>2 Checking the unit Multiple units were replaced at the same time. Be sure not to perform the following works at the same time when the memory or each PWB is replaced. • Replacing the drum unit or the developer unit • Relocating the drum units to other color’s position inside a main unit